Landmark IBD trials · Summary of an original articleLancet Gastroenterol Hepatol 2018;3:548–58

METRICMust knowCD · Imaging and monitoring

Diagnostic accuracy of magnetic resonance enterography and small bowel ultrasound for the extent and activity of newly diagnosed and relapsed Crohn's disease (METRIC): a multicentre trial

Taylor SA, et al.

Figure 1. Per-patient accuracy for small bowel Crohn's disease. Every patient had both tests; dots are estimates and lines are 95% CIs. The axis starts at 50%.
Data for this figure. Reference standard: Consensus panel diagnosis (construct reference standard)
MeasureMR enterographyUltrasoundDifference
Sensitivity for extent (primary endpoint)80% (95% CI 72–86)70% (95% CI 62–78)Difference 10% (95% CI 1–18); P=0.027
Specificity for extent95% (95% CI 85–98)81% (95% CI 64–91)Difference 14% (1–27); P=0.039
Sensitivity for presence97% (95% CI 91–99)92% (95% CI 84–96)Difference 5% (1–9); P=0.025
Specificity for presence96% (95% CI 86–99)84% (95% CI 65–94)Difference 12% (0–25); P=0.054

Both tests detect small bowel disease in most patients; the gap opens when the question is how far the disease extends.

Source: Taylor 2018, abstract.

Structured abstract

BackgroundMR enterography and ultrasound were both used to image Crohn's disease, but their comparative accuracy for disease extent and activity was not known with certainty.

MethodsProspective, multicentre diagnostic accuracy trial (8 UK hospitals); every patient had both MR enterography and ultrasound; consensus panel reference standard. 284 patients. Primary endpoint: Difference in per-patient sensitivity for small bowel disease extent (correct presence and segmental location).

ResultsPrimary result. Sensitivity for small bowel extent: 80% (95% CI 72–86) with MR enterography vs 70% (62–78) with ultrasound; difference 10% (1–18); P=0.027.

Take-homeBoth MR enterography and intestinal ultrasound detect small bowel Crohn's disease with high sensitivity; MR enterography maps extent somewhat more accurately, while ultrasound is a valid first-line, point-of-care alternative.

Table 1. Trial at a glance
Patients284
PopulationPatients aged 16 or older with newly diagnosed Crohn's disease (133) or established disease with suspected relapse (151). By the reference standard, 233 (82%) had small bowel disease.
ComparisonMR enterography vs small bowel (intestinal) ultrasound
PublishedTaylor SA, et al. Lancet Gastroenterol Hepatol 2018;3:548–58.

Key points

  • Sensitivity for small bowel disease presence was high with both: 97% (91–99) MR enterography vs 92% (84–96) ultrasound; difference 5% (1–9); P=0.025.
  • Specificity for extent: 95% (85–98) vs 81% (64–91); difference 14% (1–27); P=0.039.
  • Specificity for presence: 96% (86–99) vs 84% (65–94); difference 12% (0–25); P=0.054.
  • No serious adverse events with either test.
  • Observer agreement substudy (38 patients scanned twice): 82% agreement for small bowel disease presence in new diagnoses (kappa 0.64) and 81% in relapse (kappa 0.63) (PMID 32037466).

Limitations

  • UK National Health Service setting; ultrasound expertise and equipment vary between centres and countries.
  • Focused on diagnosis and relapse, not on monitoring response to treatment.
  • Reference standard was a consensus panel rather than surgical histology for most patients.

Commentary

METRIC is the key head-to-head comparison of the two radiation-free tests used for small bowel Crohn’s disease. It found both highly sensitive for detecting disease, with MR enterography better at mapping its extent. The authors favoured MR enterography where available in the UK system.

Since METRIC, intestinal ultrasound has become central to monitoring rather than only diagnosis: it is repeatable at the bedside, shows response within weeks (see the STARDUST ultrasound substudy and TRUST&UC), and is acceptable in pregnancy (see intestinal ultrasound in pregnancy). A practical approach is MR enterography for baseline mapping of extent, penetrating disease or surgical planning, and ultrasound for serial monitoring.

Journal club

PopulationPatients aged 16 or older with newly diagnosed Crohn's disease (133) or established disease with suspected relapse (151). By the reference standard, 233 (82%) had small bowel disease.
InterventionMR enterography
ComparisonSmall bowel (intestinal) ultrasound
Primary outcomeDifference in per-patient sensitivity for small bowel disease extent (correct presence and segmental location).

Design

Prospective, multicentre diagnostic accuracy trial (8 UK hospitals); every patient had both MR enterography and ultrasound; consensus panel reference standard. 284 patients.

Primary result. Sensitivity for small bowel extent: 80% (95% CI 72–86) with MR enterography vs 70% (62–78) with ultrasound; difference 10% (1–18); P=0.027.

Validity and applicability

  • UK National Health Service setting; ultrasound expertise and equipment vary between centres and countries.
  • Focused on diagnosis and relapse, not on monitoring response to treatment.
  • Reference standard was a consensus panel rather than surgical histology for most patients.

Where it sits now

Both MR enterography and intestinal ultrasound detect small bowel Crohn's disease with high sensitivity; MR enterography maps extent somewhat more accurately, while ultrasound is a valid first-line, point-of-care alternative.

  • STARDUST (2022): With ustekinumab, an endoscopy-driven treat-to-target algorithm did not improve 48-week endoscopic response over clinically driven care; treat-to-target only helps if escalation has something to add.
  • TRUST&UC (2020): Intestinal ultrasound shows bowel wall thickening in most UC flares and tracks response within 2 weeks, so it is a practical point-of-care tool for monitoring UC treatment.
  • Intestinal ultrasound in pregnancy (2025): In pregnancy, inflammation seen on intestinal ultrasound was associated with preterm birth, low birth weight and pre-eclampsia independently of symptoms and calprotectin; consider ultrasound to monitor IBD antenatally.

Questions for discussion

  1. The reference standard was a consensus panel. How might the way it was built affect the comparison between the two tests?
  2. Ultrasound accuracy depends on the operator. How well would these results transfer to your centre?
  3. For a newly diagnosed patient, when would you choose MR enterography over ultrasound?
Report a problem with this trial

Please don't include patient information. This form isn't for medical questions.

Try “pregnancy”, “Mayo”, “calprotectin” or “VARSITY”.